For the rail industry, complies with



                                                                                                                                    DIN EN 45545 HL3, R22/R23


                                                                                                                                    Wear-resistant for rail technology



                                                                                                                                    iglidur  RW370
                                                                                                                                                    ®






                                                                                                                                    When to use it?
                                                                                                                                    ●  For applications in rail technology where suitability according to DIN EN 45545 is required
                                                                                                                                    ●  For high wear resistance at low to medium pressures
                                                                                                                                    ●  When a low coefficient of friction in dry operation is requested
                                                                                                                                    ●  Low moisture absorption





                                                                                                                                    When not to use it?
                                                                                                                                    ●  When high pressure loads occur and suitability according to DIN EN 45545 is not required
                                                                                                                                             ®
                                                                                                                                                      ®
                                                                                                                                       iglidur  G, iglidur  W300
                                                                                                                                    ●  When temperatures higher than +190°C occur
                                                                                                                                       iglidur  G, iglidur  Z
                                                                                                                                                      ®
                                                                                                                                             ®
                                                                                                                                    ●  When a cost-effective plain bearing for occasional movements is necessary
                                                                                                                                       iglidur  G
                                                                                                                                             ®









                                                                                                                 ASEAN 09/2023   ASEAN 09/2023