6 | Hot water boilers





                Energy-saving system technology




                Highly efficient boiler systems with perfectly matched boiler house components
                ensure low energy consumption and low emissions.






                   Save energy costs through the                        Maximum availability of the system ...
                   firing ...
                                                                        ... through remote service
                   ... up to 40 % by switching fuel                     On the customer’s demand a Bosch service
                   Switching to another fuel can often have a pay-      expert can gain direct access to the system via a
                   back period of only a few months while genera-       secure connection to identify e.g. false param-
                   ting savings over decades. If multi-fuel firing is   eters quickly. In some cases these faults can be
                   retrofitted, peak loads can be covered by a          eliminated remotely, or the service technician is
                   second fuel or own biogas can be used.               able to provide the correct spare part at the first
                                                                        on-site visit.
                   ... up to 4 % by optimising the firing
                   Combustion control balances out changes in           ... through preventive condition monitoring
                   operating conditions such as temperature, pres-      The intelligent boiler control evaluates sensor signals
                   sure and gas quality. An intelligent system          during operation to detect wear or the need of
                   control and a high modulation range reduce           maintenance at an early stage. These notifications
                   unnecessary cold starts and pre-ventilation          enable higher reliability of the system and trouble-
                   losses when starting up.                             free operation.

                   ... reduce the power consumption by up to            ... through automatic functions that reduce
                   75 % through efficient electrical consumers          wear on materials
                   Conventional firing fans do not adapt their output   Frequent cold starts at high load levels create
                   to the boiler load. Speed-controlled motors and a    stress for boilers and their components. Auto-
                   burner control not only save you power, the boiler   matic boiler start functions and control algorithms
                   will also be significantly quieter at partial load.  for reducing burner starts increase the service life
                                                                        of the system.


                   Save fuel costs through heat                         ... through remote monitoring
                   recovery ...                                         An immediate message on a cell phone in the case
                                                                        of a fault makes it possible to react quickly – so
                   ... from flue gas up to 14 %                         that operation remains interruption-free.
                   The flue gas temperature can be reduced by
                   more than 100 K through the use of a flue gas
                   heat exchanger (economizer). A downstream
                   condensation heat exchanger extracts further
                   energy from heat and condensation.