Page 545 - IGUS ECS CATALOG
P. 545

E4.1L | Technical data | Overview




                        Technical data

                             Speed gliding / acceleration gliding 1)              ≤ 5 [m/s] / ≤ 25 [m/s ]
                                                                                                 2
                                       1)
                        FL G                                                                     2
                             Speed FL G  / acceleration FL G                    ≤ 20 [m/s] / ≤ 200 [m/s ]
                        FL B
                                                                                                 2
                                                                                   ≤ 3 [m/s] / ≤ 6 [m/s ]
                             Speed FL B  / acceleration FL B
                                                           ®
                             Material - permitted temperature °C, igumid  G            -40°C/+120°C
                             Flammability class, igumid  G                      VDE 0304 IIC UL94-HB
                                               ®
                               FL G  = unsupported with straight upper run    FL B  = unsupported with permitted sag
                             1) Series E4.31L / R4.31L: If a gliding application is required for a long travel, please consult igus ® .


                        Installation types, maximum travels




                        Series                                    Vertical    Vertical   Side mounted
                                         Unsupported  Gliding 1)
                                                                  hanging     standing   unsupported
                        E4.31L / R4.31L  ≤ 4.0m      upon request  ≤ 40m     ≤ 2.5m      ≤ 0.6m

                        E4.38L / R4.38L  ≤ 5.5m      ≤ 80m       ≤ 50m       ≤ 3.0m      ≤ 1.0m
                        E4.48L / R4.48L  ≤ 7.5m      ≤ 100m      ≤ 80m       ≤ 3.0m      ≤ 1.2m

                        E4.64L           ≤ 4.0m      upon request  ≤ 80m     ≤ 8.0m      ≤ 2.0m
                        1) Series E4.31L / R4.31L: If a gliding application is required for a long travel, please consult igus ® .



















                        Swarf test in the igus ®  lab - protection demonstrated in this   The light and fully enclosed R4.1 L e-tubes from igus ®  are now
                        test setup; stop-dogs completely free of swarf  available in a high-temperature version
                               3D CAD, confi gurators, service life calculation and more   www.igus-asean.com/lean  543


                    08)-ASEAN-E4-1LEAN-2022.indd   543                                       05.06.23   18:40
                    08)-ASEAN-E4-1LEAN-2022.indd   543
                                                                                             05.06.23   18:40
   540   541   542   543   544   545   546   547   548   549   550