Page 825 - IGUS ECS CATALOG
P. 825

e-skin soft | Series SKS | Product range                              SKS
                                ®
                                                                                    20-38
                        33% less clearance height than e-skin  SK28 1)
                                                         ®



                               -33%








                        Series SKS | Two-piece corrugated tube | With "zipper" opening principle

                        Part No.       Bi      Ba      hi      ha    R min.*  Cable    H F   Weight
                        SKS           [mm]    [mm]    [mm]    [mm]    [mm]   ≤ ø [mm]  [mm]  [kg/m]
                        SKS20.033.02.1  33     50      20      25     055      13   160  2)**  / 200  2)**  ≈ 0.20
                        SKS28.068.02.1  68     95      28      40     055      20     200  4)  ≈ 0.54
                        SKS40.085.02.1  85    118      38      57     100      30     350  4)  ≈ 1.15
                        1) 33% lower clearance height than e-skin ®  SK28 (based on the latest test results done in the igus ®  laboratory)
                        4) Required clearance height H F with 0.75kg/m fill weight / 2) Required clearance height H F with 0.50kg/m fill weight
                        **H F : 160mm at S < 200m / H F : 200mm at S > 200m
                        *Note: the minimum bend radius is determined by the inner side corrugated tube!

                        Installation dimensions
                                                                Ba              Inner height
                                                                 Bi
                           2.0
                          Fill weight [kg/m]  1.9 1.8 1.7 1.6                   SKS20        28 [mm]
                                                                                Inner height
                                                                                             28 [mm]
                                                                                SKS28
                           1.5
                           1.4                                     ≤ ø      hi  Inner height  38 [mm]
                           1.3                                                ha  SKS40
                           1.2          SKS40                      mm
                           1.1                                                  Energy supply    = S / 2  + K
                           1.0          FLG                                     system length  L K
                           0.9
                           0.8                                            S
                           0.7
                                                             D            S/2
                           0.6
                           0.5       SKS28
                           0.4                                            Moving end
                           0.3  SKS20  FLG
                           0.2
                             FLG
                           0.1
                           0
                             0  0.1  0.2 0.3 0.4  0.5 0.6 0.7 0.8 0.91.0  1.1 1.2 1.3 1.4 1.5  1.6 1.7 1.8 1.92.0  Fixed end  H  H F
                             Unsupported length FL G                                        H - ha
                             Travel S [m]
                                                                                          ha
                             0    1.0   2.0   3.0   4.0
                        R min.*        SKS20 R 055  SKS28 R 055  SKS40 R 100
                        H                150          150         300
                        D                125          130         300
                        K                300          266         693
                        *Note: the minimum bend radius is determined by the inner side corrugated tube!
                        No bend radius is specifi ed in the part number, since it depends on travel and fi ll weight. The smallest specifi ed radius below is the minimum to guarantee the service life of
                        the cables. In most applications, however, the radius remains larger because the shape of the tube defi nes this.
                               3D CAD, confi gurators, service life calculation and more   www.igus-asean.com/eskin  823
                    12)-ASEAN-CLEAN-E-SKIN-E6-1-2022.indd   823                              05.06.23   18:53
                                                                                             05.06.23   18:53
                    12)-ASEAN-CLEAN-E-SKIN-E6-1-2022.indd   823
   820   821   822   823   824   825   826   827   828   829   830