Page 8 - Bosch Modernisation of Boiler Systems
P. 8

8 | Modernisation of boiler systems





          Modernisation measures in detail









          Save fuel costs through heat recovery ...

          ... from flue gas up to 14 %
          The flue gas temperature can be reduced by more
          than 100 Kelvin through the use of a flue gas heat                                       A 10 % fuel
                                                                                                   saving in a
          exchanger (economizer). A downstream condensation                                        system with
          heat exchanger extracts further energy from heat and                                     10 t/h steam
          condensation.                                                                            capacity means
                                                                                                   a saving of up
                                                                                                   to 150,000
          ... from condensate up to 12 %                                                           euros per year.
          Condensate is water that has already been treated
          and that also contains energy. By feeding it back to
          the water circuit, less cold fresh water has to be
          treated and heated.

          ... from desalting up to 1 %
          Desalting water contains energy in form of pressure
          and heat that can be recovered. Further, wasting of
          fresh water to cool down this hot boiler water can be
          avoided.



          Save energy costs through the firing ...

          ... of up to 40 % by switching fuel
          Energy costs per kWh vary depending on the fuel.
          Switching to another fuel can often have a payback                                       A fuel price
                                                                                                   difference of
          period of only a few months while generating savings                                     20 % per kWh
          over decades. If multi-fuel firing is retrofitted, peak                                  saves up to
          loads can be covered by a second fuel.                                                   285,000 euros
                                                                                                   per year on
                                                                                                   a 10 ton boiler.
          ... of up to 4 % by optimising the firing
          Combustion control balances out changes in opera-
          ting conditions, such as temperature, pressure and
          gas quality – for a high level of combustion efficiency.
          Intelligent system control and a high modulation
          range reduce unnecessary cold starts and pre-ventila-
          tion losses when starting up.                                                            Reduced
                                                                                                   dependence on
                                                                                                   one fuel thanks
          ... reduce the power consumption of up to 75 %                                           to multi-fuel
          through efficient electrical consumers                                                   firing.
          Conventional firing fans are operated at 100 % load
          even when the boiler is at partial load. The excess
          energy is “destroyed” by throttling the air flow.
          Speed-controlled motors and burner control not only
          save you power, your boiler will also be significantly
          quieter at partial load.
   3   4   5   6   7   8   9   10   11   12   13