Page 773 - IGUS Linear
P. 773

Chemical resistance


          "4" swelling, softening due to water

 Chemicals, iglidur ®  A180  A200, G  A350  A500  A290  J  J260 J350  H  F2  Q  V400  Z  B  D  T220 K230  PEP  A160  E7  I170  I180  xirodur    xiros  ball bearings with  I150 C210  I3
                                                                                   ®
                                                                            ®
 A181  GLW  C500  F  J2  M260  H1  K          B160              I180-BL  D180  PEEK    PP     PA        P230  I6
 J200  G V0  UW500  Q290  J3  H2  P          UW160                             cage   cage    cage           AB
 R  M250  X  W360  J4  H370  P210         xirodur  C160                                PE
                                                ®
 UW  N54, Q2  X6  G1  JB  H4  P4                                                      cage
 xirodur  B180  W300, C  xirodur  A500  E  HLW  M210
 ®
 ®
 xirodur  S180  L250, L100  L500  iguton G
 ®
 xirodur  F180  igumid  G  AX500  H3, H5
 ®
 ®
 xirodur  M180 xirodur  G220
 ®
 ®
 FC180  igumid  FC
 ®
 Washing machine cleaner
 +  o  x  +  o  –  x  x  +  +  o  x  +  o  –  +  x  –  +  x  x    x      x      +       o      +     x   x    o
 (phosphoric and nitric acid)
 Wax, melted  +  +  +  +  +  +  +  +  +  +  +  +  +  +  +  +  x  +  o  x  +  +  x  +    x      +     x   +    +
 White spirit  +  +  x  +  +  +  o  x  +  +  +  x  +  x  +  +  x  +  x  x  x  o  x  +   +      o     x   x    +
 Xylol  o  o  +  +  +  o  –  x  +  –  +  x  +  o  –  –  +  +  –  o  –  –  x     +       x      +     x   o    +
 Zinc chloride (aqueous), 10%  –  –  x  +  +  –  –  x  +  –  o  x  +  –  –  x  o  –  +  +  +  –  x  +  –  o  x  x  –
 Zinc oxide  +  +  x  +  +  +  +  x  +  +  +  +  +  +  +  +  x  +  x  x  +  +  x  +     +      o     +   x    +
 Zinc sulphate (aq.), 10%  +   4  x  +   4  +  +  x  +  +    4  x  +  +  +  +  x    4  +  x  +  +  x  +  x  +  +  x  x
 Zinc sulphate (aqueous), 10%  +   4  x  +   4  +  +  x  +  +   4  x  +  +  +  +  x   4  +  x  +  +  x  +  x  +  +  x  x
          The data was determined using laboratory specimens or   application conditions. All data given concerns the chemical
          based on comparisons with similar chemicals. Therefore,   resistance at room temperature. Other temperatures may
          this data can only act as a reference. No interaction is also    lead to different classifications of the chemical resistance.
          considered between the single chemicals / media which can   We therefore recommend custom-designed tests under
          lead to a change of the resistance of iglidur  plain bearings.   real application conditions.
                                             ®
          The chemical resistance of actual parts should be tested under







































       ASEAN 09/2023  3D CAD files, prices and delivery time online u www.igus-asean.com                     771