Page 19 - Bosch Controls and Connectivity
P. 19

18 | Controls and connectivity                                                             Controls and connectivity | 19






 CHP control units: ideal complements  Premium buffer storage control



 The CHP module control can be supplemented with different components and options, tailored to your   Buffer cylinders increase CHP module operating time:   As with the multi-module control, all maintenance
 specific needs. One control unit can be used for multiple Bosch CHP modules and can be monitored   when heat is not being transferred, the CHP units heat   work can be undertaken at the same time – meaning

 using remote access. At the same time, the modules offer great flexibility when connecting to different   the storage cylinders in order to guarantee conti nuous   shorter downtimes. Particularly high on-site power
          operation. The premium buffer storage control allows
                                                               generation is made possible by combining the buffer
 grid operators.   for regulation of up to two CHP modules based on   cylinders with a power-controlled operation of the CHP
          buffer cylinder temperatures. Operating hours are    modules, supported by the mains draw control, for
 Multi-module control (MMS)  compared to ensure an even load across the CHP   example.
          units. The display visualises the CHP module and
          buffer storage system for easy handling and parameter
          setting.
 Using the higher-level multi-module (MMS) control for   The multi-module control has a wide range of on-site
 up to six CHP modules can avoid the need for an   interfaces, such as digital inputs for releasing the CHP
 on-site higher-level automation system. Operational   modules, external emergency stop and potential-free   At a glance
 status, confi guration and a system overview are shown   contacts for warning/fault feedback signals or starting   CHP  Storage  ▶  Control up to two CHP units without using the
 and controlled separately for each CHP unit. An oper-  a peak-load boiler. Modifications can be made depend-  on-site building management system
 ating parameter comparison is undertaken for all of   ing on the application required, thanks to the reserve   Supply   ▶  Optimised heat supply in combination with buffer
                                                    flow
 the connected CHP modules, through which the con-  contacts in a separate multi-module control cabinet   ON  cylinders
 trol strategy ensures even loading to achieve maximum   that can be freely configured.   ▶  System visualisation included
 service life. Start and stop points are pre-configured at   47 kW  OFF  ▶  Start/stop/performance control can be configured
 the factory but can also be set individually.   At a glance  Output  Return   freely
 ▶  Stand-alone control of multiple CHP units via a   flow      ▶   Even load distribution reduce overall maintenance
 Configuration of the specific operating modes allows   central, separate control cabinet saves on building   costs for the CHP module cascade
 for great flexibility:  management system (data points)        ▶  Easily combined with power-controlled operation
 ▶  Heat-controlled, based on the supply flow    ▶  An integrated display allows for both a system over-
 temperature  view and configuration using just one control device
 ▶  Heat-controlled, based on the buffer storage    ▶  Greater flexibility through configuring the control
 temperatures  logic
 ▶  Power-controlled, based on the power drawn from   ▶  A range of external interfaces, meaning further heat
 the mains   sources, can be added to the control  Control unit for power supply companies (EVU)
 ▶  Power-controlled, island mode   ▶   Avoid downtime through automatic request and
 release of CHP units as well as optimal maintenance
 planning  Ensuring maximum power grid stability through pro-  Request signals from power supply companies are, for
          viding access for the power supply companies to the   example, unrestricted performance reduction, active
          CHP control unit is regulated by law. This leads to   power specification or disconnection from the mains.
          significant extra work for the operators when setting   At the same time, feedback signals are sent regarding
          up the connection conditions. Especially challeng ing   different operating parameters, e.g. operating mode,
          are the different requirements with complex control   active power notification or power/voltage notification.
 Multi-module control as   algorithms, or regional grid operators reading out
 a higher-level automa-  certain measurement variables from generating units.
 tion system for up to six   Almost all power supply company requirements can be   At a glance
                                                               ▶   High level of flexibility through the comprehensively
 CHP modules  displayed using Bosch's power supply company control   configurable control parameters
          unit. The separate switch box is supplied with a num-  ▶   Modification of CHP unit parameters through an
          ber of input/output contacts to enable flexible configu-  external input signal from the grid operator/power
          ration. Intervention from the grid operator is visualised   supply company
          on the CHP control display and shows the reason for   ▶   Expansion of infeed management and fulfillment of
          the current CHP unit operation, allowing the oper ator   grid operator specifications as a contribution to
          to see instantly why a CHP module is operating at a     power network stability
          reduced output, for example.                         ▶   Visualisation of power supply company specifications
                                                                  for greater operating mode transparency for the
                                                                  CHP module operator
   14   15   16   17   18   19   20   21   22   23   24