CF897            PVC       iguPUR      PUR         TPE                                                                                            Basic requirements         low 1 2 3 4 5 6 7 highest                    CF897
        iguPUR                                                                                                                                                Travel distance   unsupported 1 2 3 4 5 6 ≥ 400m                   iguPUR
        15 x d                                                            ®                                                                                    Oil resistance       none 1 2 3 4 highest                          15 x d
                     Servo cable | iguPUR | chainflex  CF897                                                                     Class 3.1.3.1                       Torsion        none 1 2 3 4 ±360°



                           5,000,000                     15 x d                        10m                                       Properties and approvals  Medium
                                                                                                                                       UV resistance
                           Double strokes guaranteed     Bend radius, e-chain ®        Travel distance, e-chain ®

                                                                                                                                       Oil resistance     Oil-resistant (following DIN EN 50363-10-2), Class 3
                     z  For flexing applications                   z  Flame-retardant
                     z  iguPUR outer jacket                                                                                            Flame-retardant    According to IEC 60332-1-2, Cable Flame, VW-1, FT1, FT2 / Horizontal Flame
                     z  Oil-resistant
                     z  Shielded                                                                                                       Silicone-free      Free from silicone which can affect paint adhesion (following PV 3.10.7 – status
                                                                                                                                                          1992)
                                                                                                                                       UL verified        Certificate No. B129699: "igus 36-month chainflex cable guarantee and
                     Dynamic information                                                                                                                  service life calculator based on 2 billion test cycles per year"
                                                     ®
                           Bend radius        e-chain  linear   minimum 15 x d                                                         UL/CSA AWM         See data sheet for details  www.igus-asean.com/CF897
                                              flexible        minimum 12 x d
                                              fixed           minimum 8 x d                                                            NFPA               Following NFPA 79-2018, chapter 12.9
                           Temperature        e-chain  linear   -20°C up to +80°C
                                                     ®
                                              flexible        -40°C up to +80°C (following DIN EN 60811-504)                           EAC                Certificate No. RU C-DE.ME77.B.00302/19
                                              fixed           -50°C up to +80°C (following DIN EN 50305)
                           v max.             unsupported      3m/s                                                                    REACH              In accordance with regulation (EC) No. 1907/2006 (REACH)

                           a max.             20m/s²                                                                                   Lead-free          Following 2011/65/EC (RoHS-II/RoHS-III)


                           Travel distance    Unsupported travels up to 10m, Class 1                                                   CE                 Following 2014/35/EU

                     Cable structure                                                                                                   UKCA               In accordance with the valid regulations of the United Kingdom (as at 08/2021)
                           Conductor          Conductor consisting of bare copper wires (according to DIN EN 60228).
                                                                                                                                 Guaranteed service life (details see page 28-29)
                           Core insulation    Mechanically high-quality, especially low-capacitance TPE mixture.                 Double strokes*               1 million              3 million              5 million

                                                                                                                                       Temperature,             R min.                 R min.                R min.
                           Core structure     Power cores and control pair elements wound together in an optimised pitch               from/to [°C]            [factor x d]          [factor x d]           [factor x d]
                                              length.                                                                                    -20/-10                 17.5                  18.5                   19.5
                           Core identification  Power cores: Black cores with white numbers, one green-yellow core.                      -10/+70                  15                    16                     17
                                              1. Core: U / L1 / C / L+ 2. Core: V / L2 3. Core: W / L3 / D / L-                          +70/+80                 17.5                  18.5                   19.5
                                              1 control pair: Black cores with white numbers.                                    * Higher number of double strokes? Service life calculation online  www.igus-asean.com/chainflexlife
                                              1. Control core: 5 2. Control core: 6
                                              2 control pairs: Black cores with white numbers.                                   Typical application areas
                                              1. Control core: 5 2. Control core: 6                                              z  For flexing applications, Class 3
                                              3. Control core: 7 4. Control core: 8                                              z  Especially for unsupported travels, Class 1
                           Element shield     Foil taping of optimised, bending-resistant foil shield.                           z  With influence of oil, Class 3
                                                                                                                                 z  No torsion, Class 1
                           Overall shield     Braiding made of tinned copper wires.                                              z  Indoor and outdoor applications without direct sun radiation
                                              Coverage approx. 60% optical                                                       z  Machining units/machine tools, low temperature applications
                                                                                                              ®
                           Outer jacket       Low-adhesion iguPUR mixture, adapted to suit the requirements in e-chains .
                                              Colour: Pastel orange (similar to RAL 2003)                                                             Number of cores and conductor   Outer diameter   Copper
                                                                                                                                 Part No.                                                                          Weight
                                                                                                                                                           nominal cross section         (d) max.       index
                     Electrical information                                                                                                                       [mm²]                   [mm]         [kg/km]    [kg/km]
                           Nominal voltage    600/1,000V (following DIN VDE 0298-3)                                              1 control pair shielded
                                                                                                                                                             (4G1.5+(2x1.5)C)
                                              1,000V (following UL)                                                              CF897.15.15.02.01          (4G2.5+(2x1.5)C)C             12.5           124        201
                                                                                                                                 CF897.25.15.02.01
                                                                                                                                                                                                                    248
                                                                                                                                                                                                         182
                                                                                                                                                                                          13.5
                                              4,000V (following DIN EN 50395)
                   Example image                                                                                                 CF897.40.15.02.01          (4G4.0+(2x1.5)C)C             14.5           236        329
                           Testing voltage
                                                                                                                                 2 control pairs shielded
                                                                                                                                                                                          13.5
                                                                                                                                                           (4G1.5+2x(2x1.5)C)C
                                                                                                                                 CF897.15.15.02.02
                     EPLAN download, configurators  www.igus-asean.com/CF897                                                    Note: The given outer diameters are maximum values and may tend toward lower tolerance limits.  164  246
        290          36-month guarantee ... more than 1,350 cable types from stock ... no cutting charges           ASEAN2023  ASEAN2023  G = with green-yellow earth core   x = without earth core   ®                             291
                                                                                                                                                                 UL-verified chainflex  guarantee ... www.igus-asean.com/ul-verified