Page 307 - ASEAN Chainflex Catalogue 2023
P. 307
CF29.D PVC iguPUR PUR TPE Basic requirements low 1 2 3 4 5 6 7 highest CF29.D
TPE Travel distance unsupported 1 2 3 4 5 6 ≥ 400m TPE
6.8 x d ® Oil resistance none 1 2 3 4 highest 6.8 x d
Servo cable | TPE | chainflex CF29.D Class 7.6.4.1 Torsion none 1 2 3 4 ±360°
12.5 million 6.8 x d 400m Properties and approvals Medium
UV resistance
Double strokes guaranteed Bend radius, e-chain ® Travel distance, e-chain ®
Oil resistance Oil-resistant (following DIN EN 60811-404), bio-oil-resistant (following VDMA
z For heaviest duty applications Now available 24568 with Plantocut 8 S-MB tested by DEA), Class 4
z TPE outer jacket Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status
z Shielded with UL approval 1992)
z Oil and bio-oil-resistant & 25% longer Halogen-free Following DIN EN 60754
z PVC and halogen-free service life
z UV-resistant UL verified Certificate No. B129699: "igus 36-month chainflex cable guarantee and
z Hydrolysis and microbe-resistant service life calculator based on 2 billion test cycles per year"
UL AWM See data sheet for details www.igus-asean.com/CF29D
Dynamic information (from production date 01/2022)
Bend radius e-chain linear minimum 6.8 x d REACH In accordance with regulation (EC) No. 1907/2006 (REACH)
®
flexible minimum 5 x d
fixed minimum 4 x d Lead-free Following 2011/65/EC (RoHS-II/RoHS-III)
Temperature e-chain linear -35°C up to +100°C
®
flexible -50°C up to +100°C (following DIN EN 60811-504) Cleanroom According to ISO Class 1. The outer jacket material of this series complies with
fixed -55°C up to +100°C (following DIN EN 50305) CF9.15.07 - tested by IPA according to standard DIN EN ISO 14644-1
v max. unsupported 10m/s DESINA According to VDW, DESINA standardisation
gliding 5m/s
a max. 80m/s² CE Following 2014/35/EU
Travel distance Unsupported travels and up to 400m and more for gliding applications, Class 6 UKCA In accordance with the valid regulations of the United Kingdom (as at 08/2021)
Cable structure
Conductor Stranded conductor in especially bending-resistant version consisting of bare Guaranteed service life (details see page 28-29)
copper wires (following DIN EN 60228). Double strokes* 5 million 7.5 million 12.5 million
Core insulation Mechanically high-quality, especially low-capacitance XLPE mixture. < 10m ≥ 10m < 10m ≥ 10m < 10m ≥ 10m
Temperature,
from/to [°C] R min. R min. R min. R min. R min. R min.
Core structure Power cores with control pair elements wound with elements for high tensile [factor x d] [factor x d] [factor x d] [factor x d] [factor x d] [factor x d]
stresses. -35/-25 8.5 10 9.5 11 10.5 12
Core identification Power cores: Black cores with white numbers, one green-yellow core. -25/+90 6.8 7.5 7.5 8.5 8.5 9.5
1. Core: U / L1 / C / L+ 2. Core: V / L2 3. Core: W / L3 / D / L- +90/+100 8.5 10 9.5 11 10.5 12
1 control pair: Black cores with white numbers. * Higher number of double strokes? Service life calculation online www.igus-asean.com/chainflexlife
1. Control core: 4 2. Control core: 5
Element shield Extremely bending-resistant braiding made of tinned copper wires. Typical application areas
z For heavy-duty applications, Class 7
®
Inner jacket TPE mixture adapted to suit the requirements in e-chains . z Unsupported travels and up to 400m and more for gliding applications, Class 6
z Almost unlimited resistance to oil, also with bio-oils
Overall shield Extremely bending-resistant braiding made of tinned copper wires. z No torsion, Class 1
Coverage linear approx. 70%, optical approx. 90% z Indoor and outdoor applications, UV-resistant, Class 4
Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, z Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick
adapted to suit the requirements in e-chains . handling, cleanroom, semiconductor insertion, outdoor cranes, low-temperature applications
®
Colour: Pastel orange (similar to RAL 2003)
Electrical information Part No. Number of cores and conductor Outer diameter Copper Weight
index
Nominal voltage 600/1,000V (following DIN VDE 0298-3) nominal cross section (d) max. [kg/km] [kg/km]
[mm]
[mm²]
1,000V (following UL)
Example image Testing voltage 4,000V (following DIN EN 50395) 1 control pair shielded (4G1.5+(2x1.5)C) 13.0 145 231
CF29.15.15.02.01.D
EPLAN download, configurators www.igus-asean.com/CF29D CF29.25.15.02.01.D (4G2.5+(2x1.5)C)C 14.0 199 291
15.5
256
367
(4G4.0+(2x1.5)C)C
CF29.40.15.02.01.D
300 36-month guarantee ... more than 1,350 cable types from stock ... no cutting charges ASEAN2023 ASEAN2023 Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. 301
G = with green-yellow earth core x = without earth core