Page 330 - ASEAN Chainflex Catalogue 2023
P. 330

CF30            PVC       iguPUR      PUR         TPE                                                                                            Basic requirements         low 1 2 3 4 5 6 7 highest                     CF30
         PVC                                                                                                                                                  Travel distance   unsupported 1 2 3 4 5 6 ≥ 400m                     PVC
        7.5 x d                                                      ®                                                                                         Oil resistance       none 1 2 3 4 highest                          7.5 x d
                     Motor cable | PVC | chainflex  CF30                                                                         Class 5.5.2.2                       Torsion        none 1 2 3 4 ±360°



                           10 million                    7.5 x d                       100m                                      Properties and approvals  Medium
                                                                                                                                       UV resistance
                           Double strokes guaranteed     Bend radius, e-chain ®        Travel distance, e-chain ®

                                                                                                                                       Oil resistance     Oil-resistant (following DIN EN 50363-4-1), Class 2
                     z  For heavy duty applications
                     z  PVC outer jacket                                                                                               Flame-retardant    According to IEC 60332-1-2, Cable Flame, VW-1, FT1, FT2 / Horizontal Flame
                     z  Oil-resistant
                     z  Flame-retardant                                                                                                Silicone-free      Free from silicone which can affect paint adhesion (following PV 3.10.7 – status
                                                                                                                                                          1992)
                                                                                                                                       UL verified        Certificate No. B129699: "igus 36-month chainflex cable guarantee and
                     Dynamic information                                                                                                                  service life calculator based on 2 billion test cycles per year"
                           Bend radius        e-chain  linear   minimum 7.5 x d                                                        UL/CSA AWM         See data sheet for details www.igus-asean.com/CF30
                                                     ®
                                              flexible        minimum 6 x d
                                              fixed           minimum 4 x d                                                            NFPA               Following NFPA 79-2018, chapter 12.9
                           Temperature        e-chain  linear    +5°C up to +70°C
                                                     ®
                                              flexible        -5°C up to +70°C (following DIN EN 60811-504)                            EAC                Certificate No. RU C-DE.ME77.B.00863/20
                                              fixed           -15°C up to +70°C (following DIN EN 50305)
                           v max.             unsupported     10m/s                                                                    REACH              In accordance with regulation (EC) No. 1907/2006 (REACH)
                                              gliding         5m/s
                           a max.             80m/s²                                                                                   Lead-free          Following 2011/65/EC (RoHS-II/RoHS-III)


                           Travel distance    Unsupported travels and up to 100m for gliding applications, Class 5                     Cleanroom          According to ISO Class 2. The outer jacket material of this series complies with
                                                                                                                                                          CF5.10.07 - tested by IPA according to standard DIN EN ISO 14644-1
                           Torsion            Torsion ±90°, with 1m cable length, Class 2                                              CE                 Following 2014/35/EU


                     Cable structure                                                                                                   UKCA               In accordance with the valid regulations of the United Kingdom (as at 08/2021)
                           Conductor          Cores <10mm²: Stranded conductor in especially bending-resistant version
                                              consisting of bare copper wires (following DIN EN 60228).
                                              Cores ≥ 10mm²: Conductor cable consisting of pre-leads (following DIN EN 60228).   Guaranteed service life (details see page 28-29)
                           Core insulation    Mechanically high-quality, especially low-capacitance XLPE mixture.                Double strokes*               5 million             7.5 million            10 million

                                                                                                                                       Temperature,             R min.                 R min.                R min.
                           Core structure     Cores wound with a short pitch length around a high tensile strength centre              from/to [°C]            [factor x d]          [factor x d]           [factor x d]
                                              element.                                                                                   +5/+15                   10                    11                     12
                           Core identification  Black cores with white numbers, one green-yellow core.                                   +15/+60                 7.5                    8.5                    9.5
                                              1. Core: U / L1 / C / L+ 2. Core: V / L2                                                   +60/+70                  10                    11                     12
                                              3. Core: W / L3 / D / L- 4. Core: 4 / N                                            * Higher number of double strokes? Service life calculation online  www.igus-asean.com/chainflexlife
                           Outer jacket       Low-adhesion, oil-resistant PVC mixture, adapted to suit the requirements in
                                                      ®
                                              e-chains  (following DIN EN 50363-4-1).                                            Typical application areas
                                              Colour: jet black (similar to RAL 9005)                                            z  For heavy-duty applications, Class 5
                           CFRIP ®            Strip cables faster: a tear strip is moulded into the outer jacket                 z  Unsupported travels and up to 100m for gliding applications, Class 5
                                              Video  www.igus-asean.com/CFRIP                                                   z  Light oil influence, Class 2
                     Electrical information                                                                                      z  Torsion ±90°, with 1m cable length, Class 2
                           Nominal voltage    600/1,000V (following DIN VDE 0298-3)                                                 z Preferably indoor applications, but also outdoor ones at temperatures > 5 °C
                                              1,000V (following UL)                                                              z  Storage and retrieval units, machining units/packaging machines, quick handling, indoor cranes
                           Testing voltage    4,000V (following DIN EN 50395)




                   Example image




                     EPLAN download, configurators  www.igus-asean.com/CF30

        324          36-month guarantee ... more than 1,350 cable types from stock ... no cutting charges           ASEAN2023  ASEAN2023                         UL-verified chainflex  guarantee ... www.igus-asean.com/ul-verified  325
                                                                                                                                                                                   ®
   325   326   327   328   329   330   331   332   333   334   335